Description
Overview
Armstrong GP-2000 (from manufacturer bulletin Tables PTC-271-1 and PTC-273-1) is an externally piloted, diaphragm-actuated pressure reducing valve engineered for large-capacity steam service including heat exchangers, steam coils, rotating dryers, process equipment, and heating systems.
Pilot valve discharge acts on dual stainless steel diaphragms that position the main valve via a piston, opening a larger main valve per line size than internally piloted piston-operated regulators. With 20:1 rangeability and single-seated dead-end shutoff, the GP-2000 maintains ±1% accuracy of set pressure from 5% to 100% flow.
Features
- Dual stainless steel AISI 301 diaphragms for corrosion resistance and ±1% pressure control accuracy
- Interchangeable pilot springs (regardless of valve size) covering 0,1 to 14 barg reduced pressure
- Enclosed spring chamber prevents dirt fouling; integral strainer protects the pilot valve
- Male-and-female cast mating parts ensure alignment and reduce gasket leakage
- Hardened stainless steel AISI 420 main and pilot internals, renewable in-line without special tools
- Easily removable copper tubing for in-line troubleshooting; routing avoids bottom diaphragm housing
- Available in integral and remote-mounted pilot versions (DN150 available in integral version only)
- Optional 50% reduced ports available for all 2000 Series (capacities and Cv reduced by 50%)
Technical Data (Table PTC-271-1)
| Parameter | Specification |
|---|---|
| Application | Steam |
| Inlet Pressure | 1 - 20 barg |
| Reduced Pressure (Yellow spring)* | 0,1 - 0,2 barg (remove 1 pilot diaphragm; capacity reduced by 1/2) |
| Reduced Pressure (Yellow spring) | 0,2 - 1,5 barg |
| Reduced Pressure (Green spring) | 1 - 14 barg |
| Maximum Temperature | 232 °C |
| Minimum Differential | 0,5 barg |
| Body Material | Ductile Iron ASTM A536 (Dark Gray) |
| Main Valve / Seat | Stainless Steel AISI 420 |
| Pilot Valve / Seat | Stainless Steel AISI 420 |
| Diaphragm | Stainless Steel AISI 301 |
| Connections | BSPT (1/2” - 2”) and PN 25/40 flanged (DN15 - DN150) |
| Pressure sensing line size | 1/4” (external sensing line on request; internal sensing kit available) |
Dimensions, Weights and Cv Values
| Size | L BSPT (mm) | L PN 25/40 (mm) | A (mm) | F (mm) | H Integral (mm) | H Remote (mm) | H1 (mm) | H2 (mm) | Weight BSPT (kg) | Weight PN 25/40 (kg) | Cv |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 15 – 1/2” | 150 | 150 | 200 | 176 | 398 | 362 | 170 | 244 | 14 | 16 | 5,0 |
| 20 – 3/4” | 150 | 150 | 200 | 176 | 398 | 362 | 170 | 244 | 14 | 17 | 7,2 |
| 25 – 1” | 160 | 160 | 226 | 180 | 404 | 367 | 175 | 254 | 19 | 23 | 10,9 |
| 32 – 1 1/4” | 180 | 180 | 226 | 180 | 434 | 384 | 192 | 283 | 22 | 26 | 14,3 |
| 40 – 1 1/2” | 180 | 200 | 226 | 180 | 434 | 384 | 192 | 283 | 22 | 26 | 18,8 |
| 50 – 2” | 230 | 230 | 276 | 197 | 498 | 406 | 216 | 321 | 33 | 38 | 32,0 |
| 65 – 2 1/2” | — | 290 | 352 | 211 | 552 | 440 | 251 | 375 | — | 67 | 60,0 |
| 80 – 3” | — | 310 | 352 | 222 | 575 | 456 | 264 | 400 | — | 73 | 78,0 |
| 100 – 4” | — | 350 | 401 | 240 | 658 | 511 | 321 | 489 | — | 114 | 120,0 |
| 150 – 6” | — | 480 | 502 | — | 806 | — | 414 | 673 | — | 252 | 250,0 |
Steam Capacities (Table PTC-273-1, Selected Points in kg/h)
Maximum pressure reduction 20:1; minimum pressure reduction 85% of inlet pressure. Full capacity table reproduced across key pressure points:
| Inlet (barg) | Outlet (barg) | DN15 | DN20 | DN25 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 | DN150 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 0,5 | 89 | 128 | 194 | 255 | 335 | 571 | 1 071 | 1 392 | 2 142 | 4 465 |
| 2 | 0,2 - 0,5 | 175 | 252 | 382 | 501 | 659 | 1 123 | 2 105 | 2 737 | 4 210 | 8 769 |
| 4 | 0,2 - 1,5 | 292 | 421 | 637 | 836 | 1 099 | 1 872 | 3 510 | 4 563 | 7 020 | 14 614 |
| 6 | 0,5 - 2,5 | 409 | 589 | 892 | 1 171 | 1 539 | 2 620 | 4 913 | 6 386 | 9 826 | 20 460 |
| 8 | 0,5 - 3,5 | 526 | 758 | 1 147 | 1 505 | 1 979 | 3 369 | 6 319 | 8 214 | 12 638 | 26 306 |
| 10 | 0,5 - 4,5 | 643 | 926 | 1 402 | 1 840 | 2 419 | 4 118 | 7 721 | 10 038 | 15 442 | 32 151 |
| 12 | 1,0 - 5,5 | 760 | 1 095 | 1 657 | 2 175 | 2 859 | 4 867 | 9 126 | 11 863 | 18 252 | 37 997 |
| 15 | 1,0 - 7,0 | 936 | 1 347 | 2 040 | 2 676 | 3 519 | 5 990 | 11 231 | 14 600 | 22 462 | 46 765 |
| 20 | 1,0 - 9,5 | 1 228 | 1 769 | 2 678 | 3 513 | 4 619 | 7 862 | 14 741 | 19 164 | 29 482 | 61 380 |
Ordering Information
When ordering Armstrong GP-2000, specify:
- Model number (GP-2000 integral or remote mount; 50% reduced port if required)
- Connection size (DN15–DN150) and type (BSPT or PN 25/40 flanged)
- Inlet steam pressure, target reduced pressure (spring range), steam flow rate, and quantity